BK PRECISION 8518 CALIBRATION and BK PRECISION 8518 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 8518 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Electronic Load?
Shop for Comparable Products on our
 used Electronic Load page

 
   BK PRECISION 8518   Description / Specification:    
BK PRECISION 8518 240A 1200W Single Input Electronic Load

The BK Precision 8518 1200 W Programmable DC Electronic Load can be used for testing and evaluating a variety of DC power sources. It's wide operating ranges of up to 60 V and 240 A, flexible operating modes and excellent measurement accuracy make the 8518 well suited for characterizing DC Power supplies, DC-DC Converters, batteries, fuel cells and solar cells. The loads can operate in CC, CV, CR or CP mode while voltage/current or resistance/power values are measured and displayed in real time. Load terminals are isolated and floating. Extensive protection, including over temperature, over power, over voltage, over current and reverse polarity will help protect your valuable prototype. The DC loads are easy to use. All parameters can be set quickly and precisely from the front panel, or programmed via RS232 (included) or USB (optional) interfaces. Specifications. Input rating Voltage: 0 to 60 V. Input rating Current: 0 to 240 A. CV Mode Regulation Range: 0.1 to 18 V (Accuracy ±(0.05%+0.02% FS), Resolution 1 mV), 0.1 V to Vmax (Accuracy ±(0.05%+0.025% FS), Resolution 10 mV). CC Mode Regulation Range: 0 to 24 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to max Current (Accuracy ±(0.2%+0.15% FS), Resolution 10 mA). Current Measurement Range: 0 to 24 A (Accuracy ±(0.1%+0.1% FS), Resolution 1 mA), 0 to max Current (Accuracy ±(0.2%+0.15% FS), Resolution 10 mA). Voltage Measurement Range: 0 to 18 V (Accuracy ±(0.02%+0.02% FS), Resolution 1 mV), 0 V to Vmax (Accuracy ±(0.02%+0.025% FS), Resolution 10 mV).



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 8518. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your BK PRECISION 8518 CALIBRATION and/or BK PRECISION 8518 240A 1200W Single Input Electronic Load REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: